Poultry insurance / Insured party obligations
What to remember when holding property insurance with Compensa TU S.A.
(formerly Wiener TU S.A. Vienna Insurance Group)
Claims reporting phone: 22 469 69 69
E-mail address: szkody.korporacyjne@Wiener.pl
NOTE: this is to enable the claims settlement departments of Compensa TU S.A. (formerly Wiener TU S.A.) to take actions allowing proper and unambiguous determination of the circumstances and extent of the loss.
§1 Insured party obligations during the term of the insurance contract
Breeders covered by protection under property insurance against fortuitous events (excerpt from Compensa TU S.A. property GTC):
"During the term of the insurance contract, the insured is obliged to comply with regulations aimed at preventing the occurrence of a loss, in particular:"
Construction law provisions
Fire protection law provisions
Law provisions concerning standardisation, certification, construction and operation of technical devices and performance of technical supervision over those devices
Manufacturer's recommendations regarding installation, operating conditions and use and storage of insured devices, and taking appropriate preventive actions and all reasonable precautions to minimise the risk of occurrence or aggravation of a loss
Provisions of Annex No. 1 to the GTC (concerning protection of property against losses)
NOTE: Annex No. 1 is quite extensive and tailored to various types of activity, and not all of its provisions will apply to poultry production. Where the law provides for less stringent requirements, the provisions of Annex No. 1 to the GTC will not apply.
§2 Required periodic inspections and checks
Compliance with regulations aimed at preventing the occurrence of a loss consists in fulfilling the obligations set out in the table below. Please note the ownership status of the insured party, i.e. whether they are indeed responsible for obligations related to inspections.
| Type of installation | Legal basis | Obligation / frequency |
|---|---|---|
| Periodic inspections of electrical installations | Art. 62 of the Construction Law Act of 7 July 1994 | Building manager or owner — once every 5 years |
| Gas installation, ventilation and flue ducts | Art. 62(1) of the Construction Law Act; Regulation of the Minister of Internal Affairs and Administration of 16 August 1999 | Building owner or manager — at least once a year |
| Periodic inspection of the technical condition of boilers | Art. 62(1)(5) of the Construction Law Act | Owner or manager: — boilers >100 kW (liquid/solid fuel): every 2 years — boilers 20–100 kW / gas-fired: every 4 years |
| Refrigeration equipment in air-conditioning installations | Art. 62(1)(6) of the Construction Law Act | User of the building — once every 5 years (power >12 kW) |
| Inspection of technical condition and fitness for use | Art. 62(1)(2) of the Construction Law Act | Once every 5 years — including inspection of electrical and lightning protection installations |
| Inspection of elements exposed to atmospheric influences | Art. 62(1)(1) of the Construction Law Act | Once a year |
| Inspection of large-surface buildings (>2000 m² of built-up area or >1000 m² of roof area) | Art. 62(1)(3) of the Construction Law Act | At least twice a year (by 31 May and by 30 November) |
§3 Obligations in the event of a fortuitous event
In the event of a fortuitous event, the policyholder and the insured are obliged to:
Use available means to save the subject of insurance and prevent or reduce the extent of the loss
Immediately notify the fire brigade, police or other services if the circumstances or type of loss require the presence of those services at the place where it occurred
Immediately notify Compensa TU S.A. of the accident, stating, where possible, the cause, subject and scope of the loss, the circumstances of its occurrence and its estimated value
Provide all explanations to representatives of Compensa TU S.A. and submit evidence necessary to establish the circumstances and extent of the loss, including accounting evidence
Not alter the factual state at the place of the loss, including preserving damaged property and making it available to a representative of Compensa TU S.A. for inspection, unless necessary actions have been taken to secure property remaining after the loss or to reduce the extent of the loss.
This provision does not apply if:
Compensa TU S.A. has not undertaken actions related to claims settlement within 3 business days of the date of notification
The estimated value of the loss does not exceed PLN 20,000, in which case the policyholder shall prepare and make available the following documents:
a list of losses
a detailed description of the event
photographs taken at the scene documenting the condition of the property immediately after the loss
Claims reporting phone: 22 469 69 69
E-mail address: szkody.korporacyjne@Wiener.pl
NOTE: this is to enable the claims settlement departments of Compensa TU S.A. (formerly Wiener TU S.A.) to take actions allowing proper and unambiguous determination of the circumstances and extent of the loss.
§4 Inspection details — electrical installation
Inspection of electrical and lightning protection installations with regard to the condition of connections, fittings, protections and means of protection against electric shock, insulation resistance of conductors and earthing of installations and apparatus. The installation inspection should include visual inspection, measurements and operational tests (effectiveness of protection against electric shock measurements), and checking continuity of protective conductors.
During the inspection, the following should be checked in particular:
Condition of visible parts of conductors, insulators and their fastening
Condition of glands at the point where conductors enter connection boxes
Condition of protection against mechanical damage to conductors
Condition of protection against electric shock
Operational readiness of protective devices, automation and control
Condition of information and warning signs and markings
Inspection results should be kept for the period of use of the installation. Inspections should be carried out by persons holding qualifications required for supervision of the operation of devices, installations and power networks.
§5 Inspection details — gas installation and chimney ducts
Assessment of the technical condition of gas installations and chimney ducts (smoke, flue and ventilation) should include, among others, checking:
Implementation of recommendations from the previous periodic inspection
Changes in flue channels and ducts introduced with the owner's consent
Clearance of chimney ducts
Chimney draught (using a certified measuring device)
Occurrence of damage to ducts along their entire length
Possession of properly functioning ventilation devices (supply and exhaust)
Frequency of periodic cleaning of chimney ducts
Convenient access for cleaning and inspection
The inspection report should specify the technical condition of elements covered by the inspection, the extent of wear or damage, the scope of repair works and the order of their execution, methods and means of using elements exposed to harmful atmospheric influences, and the scope of repair works not carried out that were recommended in previous inspections.
§6 Annual vs. five-year inspection
The scope of annual and five-year inspections differs, except for the construction part of the annual inspection, which overlaps with the scope of the five-year inspection. If both inspections fall in the same calendar year, the owner or manager may carry out one inspection covering the scope of both the annual and five-year inspections.
Annual inspection (Art. 62(1)(1))
Covers checking the technical condition of:
Building elements exposed to harmful atmospheric influences
Installations and devices serving environmental protection
Gas installations and chimney ducts
Five-year inspection (Art. 62(1)(2))
Covers checking the technical condition and fitness for use of the building, including:
External layers of external partitions, wall elements, balustrades
Devices mounted on walls and the building roof
Building drainage elements and sheet metal flashings
Roof coverings
Central heating and hot water installations
Devices constituting fire protection of the building
Sewerage installation
Passages of installation connections through building walls
Inspection of electrical and lightning protection installations
Inspection of large-surface buildings (Art. 62(1)(3))
Applies to buildings with a built-up area exceeding 2000 m² or buildings with a roof area exceeding 1000 m². The inspection should be carried out at least twice a year — before and after the winter period, by 31 May and 30 November.
Claims reporting phone: 22 469 69 69
E-mail address: szkody.korporacyjne@Wiener.pl
NOTE: this is to enable the claims settlement departments of Compensa TU S.A. (formerly Wiener TU S.A.) to take actions allowing proper and unambiguous determination of the circumstances and extent of the loss.
§7 Additional information
Post-inspection documents (inspection reports) should be kept and made available upon request by the insurer.
If graphic documentation is prepared during an inspection, it should be attached to post-inspection reports.
Failure to comply with the above obligations may result in refusal or limitation of indemnity payment.