title: "Ammonia in the poultry house: read it as a trend and check the sensor every cycle"
description: "Cheap NH₃ sensors slow down over time and clog with dust. See ammonia as a trend next to the flock record and check the sensor every cycle."
url: https://dlaferm.pl/en/badania/ammonia-sensor-accuracy-and-drift-in-poultry
lang: en
---

# Ammonia in the poultry house: read it as a trend and check the sensor every cycle

> Cheap NH₃ sensors slow down over time and clog with dust. See ammonia as a trend next to the flock record and check the sensor every cycle.

Your nose gets used to ammonia within minutes, and a cheap sensor starts to react more slowly after a few weeks in dust. We collect readings from climate controllers and sensors with alarms, and we are researching and rolling out our own NH₃ sensors with reminders to check them. We build on studies that compared low-cost sensors with laboratory instruments.

## You smell ammonia only for the first few minutes

Ammonia forms when uric acid breaks down in the litter. At high concentrations it irritates the birds' airways and eyes, favors foot pad dermatitis and slows weight gain. You notice it with your nose when you walk in, but your nose adapts within minutes. That is why more and more farms install NH₃ sensors.

## A sensor that lies is worse than no sensor

The market is full of cheap electrochemical and semiconductor sensors. Makers state the range and resolution, but rarely say how a sensor behaves after several weeks in dust, humidity and ammonia. The reading decides whether ventilation kicks in on time and whether you can show the data at a welfare inspection. For gas sensors in general, see our guide to [NH₃ and CO₂ sensors](https://dlaferm.pl/en/gas-sensors-in-a-poultry-house).

## How we solve it

From the reading to a decision on ventilation and litter.

### 1. Readings from controllers and sensors in the app (working)

DlaFerm connects to the climate controllers and sensors on your farm. Readings and alarms from your houses go to the farmer's app next to the flock record. Farm monitoring is a separate topic on our site.

### 2. Our own climate and ammonia sensors (research and rollout under way)

We are researching our own poultry house climate sensors, including ammonia, and rolling them out in the same app that already handles feed level sensors in silos. We mount the sensor at bird height, with a dust shield, away from air inlets and heaters.

### 3. Ammonia as a curve over time

We show the NH₃ reading as a curve next to mortality, water use and flock age, not as a single number in green or red. It is rising, falling, or higher than at this time yesterday: that tells you more than one reading.

### 4. A reminder to check the sensor (research and rollout under way)

We are rolling out reminders to compare the sensor with a portable meter in every cycle, ideally at the end of grow-out when concentrations are highest. That way you know when you can trust the sensor.

### 5. You look for the cause

The sensor measures the effect. The cause is usually wet litter and ventilation. For ways to cut emissions, see our guide to [reducing ammonia emissions](https://dlaferm.pl/en/reducing-ammonia-emissions-in-a-poultry-house).

## What the research says

Each part of the solution rests on work from 2025–2026.

### Not every cheap sensor tracks changes in ammonia

Espina-Martin's team compared six low-cost sensors with a laboratory analyzer under controlled emissions from a poultry building at a research center. Only two types showed clear agreement: R² of 0.59–0.84 for the first and 0.7–0.9 for the second. The rest did not track concentration changes in a useful way. So choosing the sensor and checking it are part of the solution.

### A sensor ages with ammonia dose, not with the calendar

Kazda's team (2026) tested low-cost electrochemical sensors after use in cattle barns. The time a sensor needs to show half of a sudden concentration change grew with the dose of ammonia the sensor had taken in inside the building. For the most exposed units it stretched to minutes. Hence the reminder to compare with a meter every cycle.

### A dust shield saves the sensor

Parsiegel's team (2025) tested sensors for two weeks in four commercial pig houses, with data sent over LoRaWAN. Sensors covered with a membrane reached an error below 20%. Without a membrane, two of sixteen stopped working, fouled by dust and fly droppings.

### Averaging improves the reading

Yi's team (2026) compared a low-cost multi-sensor node with reference instruments in beef cattle facilities. Temperature and humidity agreed almost perfectly (R² 0.995 and 0.994), while ammonia reached R² 0.604, and the result improved after averaging readings over 10-minute windows. That is why we show a curve, not single readings. For connectivity, see our article on [wired sensors vs LoRaWAN](https://dlaferm.pl/en/wired-vs-lorawan-farm-sensors).

## What your farm gets

### A reading you can trust

A sensor checked every cycle and protected from dust gives a reading you can base a ventilation decision on.

### Faster reaction to a spike

The alarm goes to your phone, and the curve shows whether ammonia has been rising for several days or jumped after a fan switched off.

### Data for welfare inspections

The ammonia history stays with the flock. At an inspection you have the curve for the whole cycle next to the flock record.

### Let's compare your sensors

If you want to set your sensor readings against the results of these studies, write to us through the form at the bottom of the page.

## Frequently asked questions

### How does DlaFerm show ammonia?

We read data from climate controllers and sensors on your farm and show it next to the flock record, with an alarm to your phone. We are researching and rolling out our own NH₃ sensors and the ammonia curve against flock data.

### Can I use the ammonia sensor I already have?

Yes, if the controller or sensor makes its data available. It is worth comparing it with a portable meter, because studies show that cheap sensors react more slowly over time.

### How often should I check an ammonia sensor?

The studies give no single interval. They show that a sensor changes with ammonia dose. A sensible rhythm on a broiler farm is a comparison with a meter in every cycle, at the end of grow-out. A quick test: take the sensor out into fresh air. If it takes minutes rather than seconds to drop to zero, the cell has aged.

### Where should I mount an ammonia sensor in a poultry house?

At bird height, away from fresh air inlets and heaters, with a membrane or filter. In a large house one sensor is not enough, because the front and back of the building can differ clearly.

### What if there is no signal in the house?

LoRaWAN sensors work on a separate radio network with a range of up to several kilometers, without Wi-Fi. You make entries in the app offline, and they are sent when your phone picks up a signal.

### Is a cheap sensor enough to check the 20 ppm limit?

For showing a trend, yes. To compare with the legal limit, which is 20 ppm at the level of the birds' heads at higher broiler stocking density, you need a measurement checked against a reference instrument.

### What data do we collect?

Ammonia, temperature and humidity readings from controllers and sensors, alarms and flock record data.

### How do you know a sensor ages?

Kazda's team (2026) showed that sensor response time grows with ammonia dose, up to minutes. Espina-Martin's team showed that only two of six cheap sensors clearly agreed with the analyzer. Parsiegel's team (2025) showed that without a shield some sensors simply stop working.

## Sources

- [Espina-Martin P. et al. (2025). Are Ammonia Sensors Ready for Outdoor Use? ACS Omega 11(1), 917–929](https://doi.org/10.1021/acsomega.5c07873)
- [Kazda M. et al. (2026). Dynamic Response Degradation in Low-Cost Electrochemical NH₃ Sensors After Barn Exposure. IEEE Open Journal of Instrumentation and Measurement 5](https://doi.org/10.1109/ojim.2026.3736146)
- [Parsiegel R. et al. (2025). Virtual MOS Sensor Array Design for Ammonia Monitoring in Pig Barns. Sensors 25(8), 2617](https://doi.org/10.3390/s25082617)
- [Yi G. et al. (2026). Field Verification and Multi-Site Deployment of a Multi-Sensor Node for Continuous Environmental Monitoring in Commercial Beef Cattle Facilities. Animals 16(18), 2862](https://doi.org/10.3390/ani16182862)

Source: DlaFerm.pl — https://dlaferm.pl/en/badania/ammonia-sensor-accuracy-and-drift-in-poultry (as of 2026-11-23). The content may be quoted and reused with a link to the source.